Hi,
Can someone tell me how I can get 50 MHz clock waveforms that do not have significant amplitude modulation and distortion.
I have the time-base set on 50nSec and I'm measuring on a board that is connected to the PC ground, but powered from an ungrounded wall transformer. I suspect my problem is with 60 Hz, but I can not seem to remove it from impacting my high frequency measurements.
Is there a way to filter out power line frequency components.
Thanks,
Dave |
|
| Back to top |
|
 |
Sarah Guest
|
Posted: Wed Nov 10, 2004 11:03 am Post subject: |
|
|
Hi
Thank you for your post, I am sorry to hear that you are having this problem.
Unfortunately there is no way to directly filter out the frequency using the Picoscope hardware or software. Instead maybe using a high pass filter on the signal before you put it in to the unit might help?
Hope this helps
Best Regards |
|
| Back to top |
|
 |
Eastern Advanced User

Joined: 04 Nov 2004
Posts: 11
Location: New Jersey
|
Posted: Wed Nov 10, 2004 2:02 pm Post subject: removing 60 Hz |
|
|
This must be a common problem . Is there someone out there who has a better solution?
Since I'm using a "floating" notebook, I will now see if an AC grounded desktop is any better. |
|
| Back to top |
|
 |
miguelroncancio User

Joined: 16 Nov 2004
Posts: 3
|
Posted: Tue Nov 16, 2004 3:19 pm Post subject: Re: how do you get undistrored picoscope 3206 waveforms |
|
|
Hi Dave
I think for this model the sampling sate is 200 MS/sec (1 channel), in other words, each cycle of 50 Mhz signal will be sampled 4 times maximum, if you have a square wave it has higher frecuency harmonics components (say 10 times), so you will need a 500 Mhz instrument to obtain a better quality.
Miguel
| Eastern wrote: | Hi,
Can someone tell me how I can get 50 MHz clock waveforms that do not have significant amplitude modulation and distortion.
I have the time-base set on 50nSec and I'm measuring on a board that is connected to the PC ground, but powered from an ungrounded wall transformer. I suspect my problem is with 60 Hz, but I can not seem to remove it from impacting my high frequency measurements.
Is there a way to filter out power line frequency components.
Thanks,
Dave |
|
|
| Back to top |
|
 |
Eastern Advanced User

Joined: 04 Nov 2004
Posts: 11
Location: New Jersey
|
Posted: Tue Nov 16, 2004 7:48 pm Post subject: |
|
|
Thanks Miguel,
Although real-time sampling is limited at 200MS/s, ETS should work fine with 10GS/s on a repetative clock of 50MHz. I should not need a 500MHz real-time sampling scope for a repetative signal.
The analog bandwidth of 200MHz should pass the 4th harmonic, not great, but enough to show a descent square wave. |
|