Posted: Thu Jan 16, 2003 11:49 am Post subject: how to set the sample interval in labview? |
|
|
| I am using ADC 11 in labview through the function adc11_labview_single, I access it through the example of adc11.llb -> adc11_single.vi, I would like to know if there is any way to set the sample interval... because I need to get high frequency data, thank you |
|
| Back to top |
|
 |
James Guest
|
Posted: Fri Jan 17, 2003 9:35 am Post subject: Setting sample interval in LabVIEW |
|
|
Hello,
To set the sample interval, set up a procedure call in your program to the routine adc11_set_interval, which is stored in the ADC11.dll.
The arguments for this are
unsigned long adc11_set_interval( unsigned long us_for_block,
unsigned long ideal_no_of_samples,
short * channels,
short no_of_channels);
A full description of this and other modules can be found in the ADC11 manual. |
|