Problem with "Measurements".

 
Post new topic   Reply to topic    Pico Technology Forum Index -> PicoScope R6
Author Message
jom
Super User
Super User


Joined: 08 Apr 2007
Posts: 32

PostPosted: Fri Aug 10, 2007 1:33 am    Post subject: Problem with "Measurements". Reply with quote

Has anyone noticed that the time domain Vrms and the Frequency measurements are wrong. I've got a time signal at 40 kHz 2Vpp that the measuremens say are 230 mVRMS and 28 kHz.

Also, the SINAD measurement on a frequency domain needs to be "edited" then hit "OK" for it to reset or some such. Otherwise the value is wrong.

Any ideas?

jom

PS: The scope windows (both time and freq) say the waveform is 2Vpp (OdBV) and 40 kHz.
Back to top
jom
Super User
Super User


Joined: 08 Apr 2007
Posts: 32

PostPosted: Tue Aug 14, 2007 3:35 pm    Post subject: Reply with quote

Nobody has seen this problem?

jom
Back to top
picojohn
Site Admin
Site Admin


Joined: 11 Jun 2007
Posts: 391

PostPosted: Wed Aug 15, 2007 9:08 am    Post subject: Reply with quote

Hello Jom,

We are trying to understand the behaviour described in your posting:

Comment 1.
'Has anyone noticed that the time domain Vrms and the Frequency

measurements are wrong. I've got a time signal at 40 kHz 2Vpp that the

measuremens say are 230 mVRMS and 28 kHz'.

Response:
Is this always the case? We have not been able to recreate that.

Comment 2.
'Also, the SINAD measurement on a frequency domain needs to be "edited"

then hit "OK" for it to reset or some such. Otherwise the value is

wrong'.

Response:
It is unclear exactly what you mean here. Also, how did you

independantly test the SINAD value of the signal?

Would you please send the .psdata file for this behaviour to

support@picotech.com so that we can take a look at it.

Regards
John
Back to top
jom
Super User
Super User


Joined: 08 Apr 2007
Posts: 32

PostPosted: Wed Aug 15, 2007 3:35 pm    Post subject: Reply with quote

Comment #1: It is not always the case. But it did happen again yesterday with the Vrms value. I did notice yesterday that the Vrms value was ready "not enough data". This was odd since there was a LOT of data given my timebase was pretty high so as to get a good spectrum view. I'll try to get that psdata to you later today.

Comment #2: As to the SINAD. I understand your question. At some point I'll get a reading of, say, 30 dB. Then after a time, maybe I change something in the set up of the scope, the reading is entirely different, say, 1 dB. So when I say "wrong" I really mean the value had changed considerably even though the input was the same. Whether it was correct to begin with is reasonable given what was being measured and the spectrum view it gave. I then will click the mouse on the measurement and hit "edit measurement". Then I click "OK" and then the reading returns to it's original value....sometimes.

I also have tried that same "fix" with the Vrms to no avail.

Thanks for looking into this.

jom
Back to top
ziko
Site Admin
Site Admin


Joined: 01 Dec 2006
Posts: 606
Location: St Neots

PostPosted: Wed Aug 22, 2007 8:52 am    Post subject: Reply with quote

Hi Jom as John had discussed with you on email, he has managed to recreate the problem and characterised its behaviour. Just to keep you informed the problem is due to using measurement settings when huge amounts of data is being collected. The problem will be resolved in a future release of the software, however in the meantime you can reduce the number of samples that are measured by choosing to measure only between two rulers or by changing the maximum number of samples. Use auto set up to ensure that you have an optimal number of cycles on the screen.

Kind regards
Back to top
jom
Super User
Super User


Joined: 08 Apr 2007
Posts: 32

PostPosted: Thu Jan 10, 2008 1:27 am    Post subject: Reply with quote

I've notice another anomaly with some of the measurements. This time it is the "DC Average" on the scope. For some reason this is off a bit. I have the scope hooked to a DAC output along with a DVM. The scope and DMV do not give the same result. I would think they would since the DVM doesn't do any more than a DC average. On the surface this may not say much but I tried a completely different DVM (not the same make or model) and it gave the same answer as the first DVM. Am I wrong in assuming the scope measurement should give the same value?

Any ideas?

Thanks

jom
Back to top
ziko
Site Admin
Site Admin


Joined: 01 Dec 2006
Posts: 606
Location: St Neots

PostPosted: Mon Jan 14, 2008 1:15 pm    Post subject: Reply with quote

Hi Jom could you send me your .pssettings file or your .psdata file if it it is not too big. Also could you tell me what measurements are you getting and what you are expecting. If your .psdata is too big could you send the settings file and do a print screen on the waveform.

Kind regards
Back to top
jom
Super User
Super User


Joined: 08 Apr 2007
Posts: 32

PostPosted: Thu Jan 24, 2008 12:48 am    Post subject: Reply with quote

How/where do I send a file to you?

Thanks

jom
Back to top
ziko
Site Admin
Site Admin


Joined: 01 Dec 2006
Posts: 606
Location: St Neots

PostPosted: Fri Jan 25, 2008 4:27 pm    Post subject: Reply with quote

Hi could you send it to support@picotech.com

Kind regards
Back to top