| Author |
Message |
arielmedina61 Super User

Joined: 23 Sep 2005
Posts: 20
Location: Buenos Aires-Argentina
|
Posted: Thu Dec 27, 2007 1:33 pm Post subject: Showing several traces captured |
|
|
Hi:
When I use "Freeze/thaw one" and composite tool I can´t see the captured traces at the same screen.
I am working with single mode and only a channel.
Could you help me?
I use 5.16.12 PS ver and a adc212/50 and a 3204 too
Thank you and regards,
Ariel |
|
| Back to top |
|
 |
ziko Site Admin

Joined: 01 Dec 2006
Posts: 658
Location: St Neots
|
Posted: Fri Dec 28, 2007 2:28 am Post subject: |
|
|
Hi Ariel,
To get it to work you need to do the following:
Open two scope screens "View->New Scope",
Then select the "View->Freeze/Thaw one" on the desired screen
Finally select "View->New Composite "
Hope this helps.
Kind regards |
|
| Back to top |
|
 |
arielmedina61 Super User

Joined: 23 Sep 2005
Posts: 20
Location: Buenos Aires-Argentina
|
Posted: Fri Dec 28, 2007 11:49 am Post subject: |
|
|
Hi,Ziko
Thank you for your reply.
I know how this tool works, but when I capture one trace on the 2nd screen, the first one disappear and the composite screen shows only one trace. Remember I use single trigger mode. I think this tool does not work with this trigg mode.
Thank you and regards,
Ariel |
|
| Back to top |
|
 |
arielmedina61 Super User

Joined: 23 Sep 2005
Posts: 20
Location: Buenos Aires-Argentina
|
Posted: Thu Jan 03, 2008 1:30 pm Post subject: |
|
|
Hi Ziko
I am waiting for your reply!
Good year!
Ariel |
|
| Back to top |
|
 |
arielmedina61 Super User

Joined: 23 Sep 2005
Posts: 20
Location: Buenos Aires-Argentina
|
Posted: Tue Jan 08, 2008 12:11 pm Post subject: |
|
|
Hi
Any help would be very grateful!!
Thaks
Ariel |
|
| Back to top |
|
 |
markspencer Site Admin

Joined: 07 May 2003
Posts: 610
|
Posted: Wed Jan 09, 2008 9:29 am Post subject: |
|
|
Hi Ariel,
I am sorry to hear that you are experiencing this problem. I have tried to the freeze/thaw functionality with the composite view without incident
The version of the software I was using was Release 5.18.0. I noticed that you where using an older version of the software Release 5.16.12, I would recommend that you upgrade to the newer version and then try the freeze/thaw and composite function again.
The software can be downloaded from:
http://www.picotech.com/download.html |
|
| Back to top |
|
 |
arielmedina61 Super User

Joined: 23 Sep 2005
Posts: 20
Location: Buenos Aires-Argentina
|
Posted: Thu Jan 10, 2008 6:07 pm Post subject: |
|
|
Hi Mark,
Thank you for your reply.
Following your advice, I ´ve downloaded the new version 5.18.0.
However there is a problem when I use single trigger. If I use AUTO there is no problem. Also I reduced the number of samples but the the result is the same.
Changing the trigger from single to auto and vice versa the scope re start and it can capture a new trace. Then I open a Composite view and works OK.
I going to use this procedure to capture differents traces to make a comparison.
Regards,
Ariel. |
|