PostPosted: Thu Oct 25, 2007 12:54 pm    Post subject: Multiple ADC20 units running Reply with quote

Is there any possibility to run more than 4 ADC20 units multiple????
Back to top
ziko
Site Admin
Site Admin


Joined: 01 Dec 2006
Posts: 606
Location: St Neots

PostPosted: Thu Oct 25, 2007 1:09 pm    Post subject: Reply with quote

Hi yes you can have multiple units plugged into one PC logging at the same time using one instance of the software.

Kind regards
Back to top
Plewe, Joerg
Active User
Active User


Joined: 07 Feb 2006
Posts: 8
Location: Germany

PostPosted: Thu Oct 25, 2007 1:17 pm    Post subject: Reply with quote

I have 6 units of ADC20 now plugged at one PC,
but it is not possible at the moment to open more as 4 units.
Same in PicpLog-Software as in my selfmade VB6 program
Back to top
Plewe, Joerg
Active User
Active User


Joined: 07 Feb 2006
Posts: 8
Location: Germany

PostPosted: Thu Oct 25, 2007 1:37 pm    Post subject: Reply with quote

see attached pictures


SelfmadeSoftware.JPG
 Description:
Picture of selfmade application

Download
 Filename:  SelfmadeSoftware.JPG
 Filesize:  247.35 KB
 Downloaded:  1137 Time(s)


PicoLog.JPG
 Description:
Picture of PicoLog

Download
 Filename:  PicoLog.JPG
 Filesize:  65.52 KB
 Downloaded:  1140 Time(s)


Device Manager.JPG
 Description:
Picture of Devices

Download
 Filename:  Device Manager.JPG
 Filesize:  112.01 KB
 Downloaded:  1139 Time(s)

Back to top
ziko
Site Admin
Site Admin


Joined: 01 Dec 2006
Posts: 606
Location: St Neots

PostPosted: Fri Oct 26, 2007 9:32 am    Post subject: Reply with quote

Hi I assume you are using an old version of the software. As we recently unlocked the number of devices you can connect to your PC. You can have up to 20 USB device.

Please download the latest software from our website:

http://www.picotech.com/software.html

Kind regards
Back to top
Plewe, Joerg
Active User
Active User


Joined: 07 Feb 2006
Posts: 8
Location: Germany

PostPosted: Mon Oct 29, 2007 12:25 pm    Post subject: Reply with quote

Hi,
now i have installed newest version (PicoFull_r5_17_1).
But, there is still the same problem as before:
PicoLog opens only 4 units of ADC20!!!!!!!
(6 Units are plugged and recognized by the Device Manager)
Back to top
ziko
Site Admin
Site Admin


Joined: 01 Dec 2006
Posts: 606
Location: St Neots

PostPosted: Tue Oct 30, 2007 3:51 pm    Post subject: Reply with quote

Aha! good point, my mistake. Whilst most of our USB devices do allow more than 4 units the ADC20/24 is limited to 4 units. We are in the process of reviewing this.

I shall keep you informed of any progress.

Kind regards
Back to top
Plewe, Joerg
Active User
Active User


Joined: 07 Feb 2006
Posts: 8
Location: Germany

PostPosted: Wed Oct 31, 2007 8:58 am    Post subject: Reply with quote

Ok, it is very very important for us!!!!
Now we have about 40 units (different types) from your company in use.
So i think, we are a good customer of you!

I look forward to your driver modification.
Back to top
ziko
Site Admin
Site Admin


Joined: 01 Dec 2006
Posts: 606
Location: St Neots

PostPosted: Wed Oct 31, 2007 12:22 pm    Post subject: Reply with quote

Hi I am pleased to say that I have attached a dll that unlocks the number of devices (20 devices in PicoLog).

I have to say though this is a pre release version, we would need to do more testing but let us know if you encounter any difficulties. Having said that I just tested it on 10 units on a short run, with no problems.

You would first need to unplug all your devices, close the software.
You will need to unzip the attached file, copy and paste it in the PicoFull folder, by default in c:\Program Files\Pico Technology\Pico Full and replace the old one. Then plug your units back in and load up PicoLog.

Let me know if you have any problems.

Kind regards



PicoHRDL.zip
 Description:

Download
 Filename:  PicoHRDL.zip
 Filesize:  65.66 KB
 Downloaded:  80 Time(s)

Back to top
Plewe, Joerg
Active User
Active User


Joined: 07 Feb 2006
Posts: 8
Location: Germany

PostPosted: Tue Nov 06, 2007 11:14 am    Post subject: Reply with quote

Ok, thanks a lot!
Inside my application it is also running!
Now i will start a "long endurance test" for more then 10000 hours with my equipment, i will tell you if there are any problems appearence.
Once again, thank you for you very fast help!
Back to top
ziko
Site Admin
Site Admin


Joined: 01 Dec 2006
Posts: 606
Location: St Neots

PostPosted: Wed Nov 07, 2007 11:34 am    Post subject: Reply with quote

No problem, would be intrigued to see how your test went.