AC Voltage Display

 
Post new topic   Reply to topic    Pico Technology Forum Index -> PicoScope
Author Message
B. Sager
Guest





PostPosted: Sat May 08, 2004 12:58 pm    Post subject: AC Voltage Display Reply with quote

Hi

I want to use my ADC212-50 for an RMS AC voltage measurement(50Hz).
How can I display the voltage in an curve (i.e. 0.5s / div) and not only in digits?

many thanks for help

B. Sager
Back to top
markspencer
Site Admin
Site Admin


Joined: 07 May 2003
Posts: 610

PostPosted: Mon May 10, 2004 8:17 am    Post subject: Reply with quote

Hi,

Thank you for your post.

To display the RMS voltage as a trace use the Scope viewer.

Connect the signal to the BNC connector of the unit, activate the channel. You should then see a trace displayed on the Scope viewer. Select the timebase that you want 500ms/div. If using a probe that is not x1, select the probe multiplier:

Settings | Probes

Best regards,
Back to top
Guest






PostPosted: Mon May 10, 2004 4:48 pm    Post subject: Reply with quote

Hi

Thank You for answer

With the scope viewer and 5ms/div timebase I get the 50Hz curve as usual. In the Measurement list I can choose "AC Voltage Whole trace" and get the AC Voltige in the scope window. I think this is the calculated true RMS Voltage (not average ?). By reducing the time base to 500ms/div
or less I naturally get an unstable curve that can not be well interpreted.

How can I display the AC Voltage movement in an curve with picoscope software ? I think it is not an good solution to use an analog RMS to DC converter in front of the ADC when the software can do the job more accurately.

many thanks for your help

B. Sager
Back to top
markspencer
Site Admin
Site Admin


Joined: 07 May 2003
Posts: 610

PostPosted: Tue May 11, 2004 7:38 am    Post subject: Reply with quote

Hi,

Thank you for the additional information.

If you are unable to get a stable or accurate scope trace at 500ms/div this is due to the sampling rate being used. The sample rate the unit uses and the timebase in the software are not the same.

The software selects the best sample rate achiveable to get the maximum number of samples that you have in:

Settings | Options | Advanced.

You could try reducing this number of samples as default 2500 samples are set as the maximum.

If you wish to choose the sample rate yourself, and to collect a precise number of samples it would be achievable in Picolog, running 'Fast Block' mode.

Best regards,
Back to top