PeterF Site Admin

Joined: 07 Jun 2007
Posts: 117
Location: Cambridgeshire
|
Posted: Thu May 22, 2008 2:35 pm Post subject: |
|
|
After some measuring of voltages the problem was solved:-
I have checked the various voltages and found the culprit.
�
Measuring between the GND connection of the 120 ohm resistor, and chassis earth I get:
�
From the Contrec Flow Meter,���� 0 Volts
From the ADC Gas Analyser��� ~12 Volts
�
And on the GND pins of the ADC11 when connected to our PC, 0 Volts.
�
It looks like I am going to have to isolate the signals from the Analyser!
|
|