PicoScope3206 timebase problems?

 
Post new topic   Reply to topic    Pico Technology Forum Index -> PicoScope
Author Message
Guest






PostPosted: Mon Apr 24, 2006 1:41 pm    Post subject: PicoScope3206 timebase problems? Reply with quote

Can't run the scope at a timebase <50ns/division ?

I've bought the 3206 because of 1ns/division !!!
Back to top
Guest






PostPosted: Tue Apr 25, 2006 8:03 am    Post subject: 3206 and Timebase <50ns/division Reply with quote

I installed the Software Version 5.13.7.
The Minimum Time per division is 50ns.

Is there something special I have to do ?
I need at least 5ns per division.

Thanks
Back to top
cjcoffin
User
User


Joined: 20 Apr 2006
Posts: 2

PostPosted: Tue May 02, 2006 9:37 am    Post subject: 3206 and Timebase <50ns/division Reply with quote

Silly question but did you use the X expansion facility, maybe the max speed refers to that?
Back to top
Sarah
Guest





PostPosted: Tue May 02, 2006 2:56 pm    Post subject: Reply with quote

Hi

1ns per division should be accessible when using ETS triggering. ETS mode can only be used with repetitive signals.

Best Regards
Back to top