PostPosted: Thu Aug 26, 2004 3:35 pm    Post subject: accelerometer data logging application Reply with quote

Hi

I was hoping to get some advice on the best PicoScope to purchase for the following single channel application.

The application requires 60 seconds of accelerometer signal to be recorded at 400 Samples/s = 24000 samples. I would like to display and do further processing of the amplitude versus time data in Excel.

(The accelerometer pre-amplifier has a switchable gain allowing a maximum output voltage of +-5V via a BNC connector. The pre-amplifier anti-alias filter has a cut-off frequency of 100Hz.)

Regards

Adam
Back to top
Sarah
Guest





PostPosted: Fri Aug 27, 2004 10:57 am    Post subject: Reply with quote

Hi Adam

Thank you for your post.

In order to record the 24000 samples that you wish to, I would recommend using either our ADC-212/3 or ADC-212/50 oscilloscope.

The ADC-212/3 has 32k of internal buffer memory. It has a maximum sampling rate of 3MS/s and a 16 bit resolution. It will enable you to record the samples you wish. The ADC-212/50 has 128k of memory so would enable you to record on both channels for the length of time needed.

In order to specify the sample rate that you wish, you will need to use the Picolog software, you will need to use it in Fast Block Mode. Once it has recorded the data you can export it to Excel.

Hope this helps

Best Regards
Back to top
Guest






PostPosted: Sat Aug 28, 2004 3:04 pm    Post subject: Reply with quote

Thanks for advice.

Adam
Back to top
lcliang@bksv.com.tw
Guest





PostPosted: Tue Nov 02, 2004 6:11 am    Post subject: Re: accelerometer data logging application Reply with quote

adam wrote:
Hi

I was hoping to get some advice on the best PicoScope to purchase for the following single channel application.

The application requires 60 seconds of accelerometer signal to be recorded at 400 Samples/s = 24000 samples. I would like to display and do further processing of the amplitude versus time data in Excel.

(The accelerometer pre-amplifier has a switchable gain allowing a maximum output voltage of +-5V via a BNC connector. The pre-amplifier anti-alias filter has a cut-off frequency of 100Hz.)

Regards

Adam