| Author |
Message |
tmcdonagh Guest
|
Posted: Tue Nov 11, 2003 10:08 pm Post subject: ADC16 Trigger setup |
|
|
I would like to set up a trigger event with my ADC16 to collect data for a specified period of time. After the collection period, I would like for the unit to recycle, increment the filename, and wait for another trigger event before collecting data. Is it possible to use the ADC16 to accept a trigger event such as a contact closure?
Thanks,
Tom |
|
| Back to top |
|
 |
markspencer Site Admin

Joined: 07 May 2003
Posts: 610
|
Posted: Wed Nov 12, 2003 11:41 am Post subject: |
|
|
Hi,
The ADC-16, is not capable of using triggers as its sample rate is only 1.5Hz, therefore it cannot be used in 'Fast Block' mode which is required for the trigger to be set.
Best regards, |
|
| Back to top |
|
 |
|
Powered by phpBB © 2001, 2005 phpBB Group
|