| Author |
Message |
Jasper User

Joined: 17 Mar 2008
Posts: 4
|
Posted: Sat May 17, 2008 9:13 am Post subject: Copectrumllecting and Displaying S |
|
|
I am looking to collect and display 2 vibration spectrums / ffts at the same time.
i am using standard vibration sensors (100 mv/g) output from Monitran
i have a picolog adc 11, can i use this or do i need a picoscope
Thanks
Jasper  |
|
| Back to top |
|
 |
picojohn Site Admin

Joined: 11 Jun 2007
Posts: 391
|
Posted: Mon May 19, 2008 10:16 am Post subject: |
|
|
Hello Jasper,
Using the ADC-11 will yield a maximum frequency range of 5 Khz for unipolar signals only (0 to 2.5 V).
For vibration work, customers typically choose a 12-bit PicoScope (http://www.picotech.com/picoscope3000.html).
In choosing which product is most suited to your requirement, you may wish to consider the required vertical resolution and spectrum range.
Regards
John |
|