ADC11 connected to two 4-20 mA instruments

 
Post new topic   Reply to topic    Pico Technology Forum Index -> USB PC Data Loggers
Author Message
peterb
Newbie


Joined: 18 Apr 2008
Posts: 1
Location: Malvern WORCS UK

PostPosted: Fri Apr 18, 2008 10:46 am    Post subject: ADC11 connected to two 4-20 mA instruments Reply with quote

I hope some one can help with this !!
I have been using the ADC with one instrument for some time with perfect results. This circuit is from a battery powered unit so I have had to wire in a 24V DC supply.
The additional instrument is 3 channel and mains powered and when I connect it to the ADC Terminal board all the voltages look correct but when it is plugged into the ADC the 3 new lines go to maximum.

I believe it could be something to do with different ground potentials but have not been able to figure it out!

I have attached a pdf of the circuit to make it easier to understand.

Thanks



Contrec 4-20 mA Output.pdf
 Description:

Download
 Filename:  Contrec 4-20 mA Output.pdf
 Filesize:  49.71 KB
 Downloaded:  40 Time(s)

Back to top
PeterF
Site Admin
Site Admin


Joined: 07 Jun 2007
Posts: 80
Location: Cambridgeshire

PostPosted: Thu May 22, 2008 2:35 pm    Post subject: Reply with quote

After some measuring of voltages the problem was solved:-

I have checked the various voltages and found the culprit.

Measuring between the GND connection of the 120 ohm resistor, and chassis earth I get:

From the Contrec Flow Meter,���� 0 Volts
From the ADC Gas Analyser��� ~12 Volts

And on the GND pins of the ADC11 when connected to our PC, 0 Volts.

It looks like I am going to have to isolate the signals from the Analyser!
Back to top