PicoScope 9200 Oscilloscope Specifications

Channels (vertical)
Channels 2 (simultaneous acquisition)
Bandwidth
Full
Narrow

DC to 12 GHz
DC to 8 GHz
Pulse response rise time
Full bandwidth
Narrow bandwidth
10% to 90%, calculated from Tr - 0.35/BW
29.2 ps
43.7 ps
RMS noise, maximum
Full bandwidth
Narrow bandwidth
With averaging

2 mV
1.5 mV
100 µV system limit
Scale factors (sensitivity) 2 mV/div to 500 mV/div.
1-2-5 sequence and 0.5% fine increments
Nominal input impedance (50 ±1) Ω
Input connectors SMA (F)
Timebase (horizontal)
Timebases 10 ps/div to 50 ms/div (main, intensified, two delayed, or dual delayed)
Delta time interval accuracy
For horizontal scale > 450 ps/div

For horizontal scale = 450 ps/div

±0.2% of Delta Time Interval ±15 ps at a temperature within ±3 °C of horizontal calibration temperature.
±15 ps or ±5% of Delta Time Interval ±5 ps, whichever is smaller at a temperature within ±3°C of horizontal calibration temperature.
Time interval resolution 200 fs  minimum
Trigger
Trigger sources External direct trigger, external prescaled trigger, internal clock trigger, clock recovery trigger (not 9201A)
Direct trigger bandwidth and sensitivity
DC to 100 MHz
100 MHz to 1 GHz


100 mV p-p
Increasing linearly from 100 mV  p-p to 200 mV  p-p
Prescaled trigger bandwidth and sensitivity
1 to 7 GHz
7 to 8 GHz
8 to 10 GHz typical


200 MV  p-p to 2 V  p-p
300 mV  p-p to 1 V  p-p
400 mV  p-p to 1 V  p-p
Trigger RMS jitter, maximum 4 ps + 20 ppm of delay setting
Data Acquisition
ADC resolution 16 bits
Digitising rate DC to 200 kHz  maximum
Acquisition modes Sample (normal), average, envelope
Data record length 32 to 4096 points maximum per channel in x2 sequence
Display
Display resolution Variable
Display style Dots, vectors, variable or infinite persistence, variable or infinite grey scaling, variable or infinite colour grading
Measurement and Analysis
Marker Vertical bars, horizontal bars (measure volts) or waveform markers (x and +)
Automatic measurements Up to 40 automatic pulse measurements
Histogram Vertical or horizontal
Mathematics Up to four math waveforms can be defined and displayed
FFT Up to two fast Fourier transforms can be run simultaneously with the built in filters (rectangular, Nicolson, Hann, flat-top, Blackman-Harris and Kaiser-Bessel)
Eye diagram Automatically characterises NRZ and RZ eye patterns. Measurements are based on statistical analysis of the waveform.
Mask test Acquired signals are tested for fit outside areas defined by up to eight polygons. Standard or user-defined masks can be selected.
Clock Recovery and Pattern Sync Trigger (PicoScope 9211A only)
Clock recovery sensitivity
12.3 Mb/s to 1 Gb/s
1 Gb/s to 2.7 Gb/s

50 mV  p-p
100 mV  p-p
Continuous rate
Pattern sync trigger 10 Mb/s to 8 Gb/s with pattern length from 7 to 65,535 max.
Recover clock RMS trigger jitter, maximum 1 ps  + 1.0% of unit interval
Maximum safe trigger input voltage ±2 V (DC + peak AC)
Trigger input connector SMA (F)
Signal Generator Output (PicoScope 9211A and 9231A)
Rise/fall times 100 ps  (20% to 80%) typical
Modes Step, coarse timebase, pulse, NRZ, RZ
Optical-electrical (O/E) Converter (PicoScope 9221A and 9231A)
Unfiltered bandwidth DC to 8 GHz  typical.
DC to 7 GHz  guaranteed at full electrical bandwidth
Effective wavelength range 750 nm  to 1650 nm
Calibrated wavelengths 850 nm (MM), 1310 nm (MM/SM), 1550 nm (SM)
Transition time 10% to 90% calculated from Tr - 0.48 / BW: 60 ps max.
RMS noise, maximum 4 µW (1310 and 1550 nm), 6 µW (850 nm)
Scale factors (sensitivity) 1 µV/div to 400 µV/div (full scale is 8 divisions)
DC accuracy, typical ±25 µW ±10% of vertical scale
Maximum input peak power +7 dBm  (1310 nm)
Fiber input Single-mode (SM) or multi-mode (MM)
Fiber input connector FC/PC
Input return loss
SM
MM

-24 dB, typical
-16 dB, typical; -14 dB, maximum
PC Requirements
Processor Pentium-class processor or equivalent
Memory 256 MiB
Disk space PicoScope 9000 software requires aproximately 30 MiB
Operating system 32–bit edition of Windows XP (SP2 or above), 32– or 64–bit edition of Windows Vista or Windows 7
Ports USB 1.1 compliant port minimum.
USB 2.0 compliant port recommended.
Environmental
Operating environment
Temperature range

Humidity

+5 °C to +35 °C for normal operation
+15 °C to 25 °C for stated accuracy
Up to 85% RH, non–condensing, at +25 °C
Storage environment
Temperature range
Humidity

-20 °C to +50 °C
Up to 95% RH, non–condensing
Physical Properties
Dimensions 170 x 255 x 40 mm   (6.7 x 10.0 x 1.6 in)
Weight 1.1 kg  max (2.3 lb)
Software
PicoScope 9000 for Windows PicoScope 9000 software is capable of many advanced features such as mathematical analysis, histogram analysis, eye-diagram analysis and mask testing. All features are included as standard. Updates can be downloaded for free.
Software development kit The SDK allows you to control the scope from your own program. The software can act as an ActiveX COM server, allowing any program to send commands to it using a standard Windows protocol. This is ideal for production–test environments where multiple scopes need to be controlled from a single PC, or where automated tests need to be run. The SDK contains full documentation and example code for various programming languages.
Language Support
Documentation
User’s guide
Quick start guide
Programmer’s guide

English
English
English
General
Additional hardware (supplied) 2 x SMA M-F connector savers (supplied fitted to scope)
Additional SMA M-F connector saver (9221A and 9231A only)
TDR Accessory Kit (PicoScope 9211A and 9231A only)
LAN patch and crossover cables (9211A and 9231A only)
USB 2.0 cable
AC adaptor
Tough carry case
TDR Accessory Kit contents
(supplied with PicoScope 9211A and 9231A only)
30 cm  precision cable
80 cm  precision cable
0 Ω  short
50 Ω  terminator
Coupler
Resistive power divider
SMA wrench
PC connection USB 2.0 (USB 1.1 compatible)
LAN connection 10/100 Mb/s (PicoScope 9211A and 9231A only)
Power supply
PicoScope 9201A
PicoScope 9211A
PicoScope 9221A
PicoScope 9231A
AC adaptor

+6 V DC ±5%. @ 1.9 A  max
+6 V DC ±5%. @ 2.6 A  max
+6 V DC ±5%. @ 2.3 A  max
+6 V DC ±5%. @ 2.9 A  max
Mains adaptor supplied for USA, UK, Europe and Australasia
Compliance FCC (EMC), CE (EMC and LVD)
Total Satisfaction Guarantee In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days.
Warranty 2 years (1 year for input sampler)
Ordering Information
Model PicoScope 9201A PicoScope 9211A
Cat number PP463 PP473
Lead time In stock In stock
Price £5,995·00  
US$9,891·75*
€7.253,95*
£7,495·00  
US$12,366·75*
€9.068,95*
Order online
Order from a distributor Find my local distributor
 
Model PicoScope 9221A PicoScope 9231A
Cat number PP654 PP664
Lead time In stock Despatched within 1-2 weeks
Price £12,495·00  
US$20,616·75*
€15.118,95*
£13,995·00  
US$23,091·75*
€16.933,95*
Order online
Order from a distributor Find my local distributor

* US Dollar and Euro prices are approximate. You will be billed in Pounds Sterling (GBP).