PicoScope 9200 Oscilloscope Specifications
| Channels (vertical) | |
|---|---|
| Channels | 2 (simultaneous acquisition) |
| Bandwidth Full Narrow | DC to 12 GHz DC to 8 GHz |
| Pulse response rise time Full bandwidth Narrow bandwidth | 10% to 90%, calculated from Tr - 0.35/BW 29.2 ps 43.7 ps |
| RMS noise, maximum Full bandwidth Narrow bandwidth With averaging | 2 mV 1.5 mV 100 µV system limit |
| Scale factors (sensitivity) | 2 mV/div to 500 mV/div. 1-2-5 sequence and 0.5% fine increments |
| Nominal input impedance | (50 ±1) Ω |
| Input connectors | SMA (F) |
| Timebase (horizontal) | |
|---|---|
| Timebases | 10 ps/div to 50 ms/div (main, intensified, two delayed, or dual delayed) |
| Delta time interval accuracy For horizontal scale > 450 ps/div For horizontal scale = 450 ps/div | ±0.2% of Delta Time Interval ±15 ps at a temperature within ±3 °C of horizontal calibration temperature. ±15 ps or ±5% of Delta Time Interval ±5 ps, whichever is smaller at a temperature within ±3°C of horizontal calibration temperature. |
| Time interval resolution | 200 fs minimum |
| Trigger | |
|---|---|
| Trigger sources | External direct trigger, external prescaled trigger, internal clock trigger, clock recovery trigger (not 9201A) |
| Direct trigger bandwidth and sensitivity DC to 100 MHz 100 MHz to 1 GHz | 100 mV p-p Increasing linearly from 100 mV p-p to 200 mV p-p |
| Prescaled trigger bandwidth and sensitivity 1 to 7 GHz 7 to 8 GHz 8 to 10 GHz typical | 200 MV p-p to 2 V p-p 300 mV p-p to 1 V p-p 400 mV p-p to 1 V p-p |
| Trigger RMS jitter, maximum | 4 ps + 20 ppm of delay setting |
| Data Acquisition | |
|---|---|
| ADC resolution | 16 bits |
| Digitising rate | DC to 200 kHz maximum |
| Acquisition modes | Sample (normal), average, envelope |
| Data record length | 32 to 4096 points maximum per channel in x2 sequence |
| Display | |
|---|---|
| Display resolution | Variable |
| Display style | Dots, vectors, variable or infinite persistence, variable or infinite grey scaling, variable or infinite colour grading |
| Measurement and Analysis | |
|---|---|
| Marker | Vertical bars, horizontal bars (measure volts) or waveform markers (x and +) |
| Automatic measurements | Up to 40 automatic pulse measurements |
| Histogram | Vertical or horizontal |
| Mathematics | Up to four math waveforms can be defined and displayed |
| FFT | Up to two fast Fourier transforms can be run simultaneously with the built in filters (rectangular, Nicolson, Hann, flat-top, Blackman-Harris and Kaiser-Bessel) |
| Eye diagram | Automatically characterises NRZ and RZ eye patterns. Measurements are based on statistical analysis of the waveform. |
| Mask test | Acquired signals are tested for fit outside areas defined by up to eight polygons. Standard or user-defined masks can be selected. |
| Clock Recovery and Pattern Sync Trigger (PicoScope 9211A only) | |
|---|---|
| Clock recovery sensitivity 12.3 Mb/s to 1 Gb/s 1 Gb/s to 2.7 Gb/s | 50 mV p-p 100 mV p-p Continuous rate |
| Pattern sync trigger | 10 Mb/s to 8 Gb/s with pattern length from 7 to 65,535 max. |
| Recover clock RMS trigger jitter, maximum | 1 ps + 1.0% of unit interval |
| Maximum safe trigger input voltage | ±2 V (DC + peak AC) |
| Trigger input connector | SMA (F) |
| Signal Generator Output (PicoScope 9211A and 9231A) | |
|---|---|
| Rise/fall times | 100 ps (20% to 80%) typical |
| Modes | Step, coarse timebase, pulse, NRZ, RZ |
| Optical-electrical (O/E) Converter (PicoScope 9221A and 9231A) | |
|---|---|
| Unfiltered bandwidth | DC to 8 GHz typical. DC to 7 GHz guaranteed at full electrical bandwidth |
| Effective wavelength range | 750 nm to 1650 nm |
| Calibrated wavelengths | 850 nm (MM), 1310 nm (MM/SM), 1550 nm (SM) |
| Transition time | 10% to 90% calculated from Tr - 0.48 / BW: 60 ps max. |
| RMS noise, maximum | 4 µW (1310 and 1550 nm), 6 µW (850 nm) |
| Scale factors (sensitivity) | 1 µV/div to 400 µV/div (full scale is 8 divisions) |
| DC accuracy, typical | ±25 µW ±10% of vertical scale |
| Maximum input peak power | +7 dBm (1310 nm) |
| Fiber input | Single-mode (SM) or multi-mode (MM) |
| Fiber input connector | FC/PC |
| Input return loss SM MM | -24 dB, typical -16 dB, typical; -14 dB, maximum |
| PC Requirements | |
|---|---|
| Processor | Pentium-class processor or equivalent |
| Memory | 256 MiB |
| Disk space | PicoScope 9000 software requires aproximately 30 MiB |
| Operating system | 32–bit edition of Windows XP (SP2 or above), 32– or 64–bit edition of Windows Vista or Windows 7 |
| Ports | USB 1.1 compliant port minimum. USB 2.0 compliant port recommended. |
| Environmental | |
|---|---|
| Operating environment Temperature range Humidity | +5 °C to +35 °C for normal operation +15 °C to 25 °C for stated accuracy Up to 85% RH, non–condensing, at +25 °C |
| Storage environment Temperature range Humidity | -20 °C to +50 °C Up to 95% RH, non–condensing |
| Physical Properties | |
|---|---|
| Dimensions | 170 x 255 x 40 mm (6.7 x 10.0 x 1.6 in) |
| Weight | 1.1 kg max (2.3 lb) |
| Software | |
|---|---|
| PicoScope 9000 for Windows | PicoScope 9000 software is capable of many advanced features such as mathematical analysis, histogram analysis, eye-diagram analysis and mask testing. All features are included as standard. Updates can be downloaded for free. |
| Software development kit | The SDK allows you to control the scope from your own program. The software can act as an ActiveX COM server, allowing any program to send commands to it using a standard Windows protocol. This is ideal for production–test environments where multiple scopes need to be controlled from a single PC, or where automated tests need to be run. The SDK contains full documentation and example code for various programming languages. |
| Language Support | |
|---|---|
| Documentation User’s guide Quick start guide Programmer’s guide | English English English |
| General | |
|---|---|
| Additional hardware (supplied) | 2 x SMA M-F connector savers (supplied fitted to scope) Additional SMA M-F connector saver (9221A and 9231A only) TDR Accessory Kit (PicoScope 9211A and 9231A only) LAN patch and crossover cables (9211A and 9231A only) USB 2.0 cable AC adaptor Tough carry case |
| TDR Accessory Kit contents (supplied with PicoScope 9211A and 9231A only) | 30 cm precision cable 80 cm precision cable 0 Ω short 50 Ω terminator Coupler Resistive power divider SMA wrench |
| PC connection | USB 2.0 (USB 1.1 compatible) |
| LAN connection | 10/100 Mb/s (PicoScope 9211A and 9231A only) |
| Power supply PicoScope 9201A PicoScope 9211A PicoScope 9221A PicoScope 9231A AC adaptor | +6 V DC ±5%. @ 1.9 A max +6 V DC ±5%. @ 2.6 A max +6 V DC ±5%. @ 2.3 A max +6 V DC ±5%. @ 2.9 A max Mains adaptor supplied for USA, UK, Europe and Australasia |
| Compliance | FCC (EMC), CE (EMC and LVD) |
| Total Satisfaction Guarantee | In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days. |
| Warranty | 2 years (1 year for input sampler) |
| Ordering Information | ||
|---|---|---|
| Model | PicoScope 9201A | PicoScope 9211A |
| Cat number | PP463 | PP473 |
| Lead time | In stock | In stock |
| Price | £5,995·00 US$9,891·75* €7.253,95* | £7,495·00 US$12,366·75* €9.068,95* |
| Order online | ||
| Order from a distributor | Find my local distributor | |
| Model | PicoScope 9221A | PicoScope 9231A |
| Cat number | PP654 | PP664 |
| Lead time | In stock | Despatched within 1-2 weeks |
| Price | £12,495·00 US$20,616·75* €15.118,95* | £13,995·00 US$23,091·75* €16.933,95* |
| Order online | ||
| Order from a distributor | Find my local distributor | |
* US Dollar and Euro prices are approximate. You will be billed in Pounds Sterling (GBP).
Contact us to ask about the PicoScope 9200 range or to arrange a demonstration >
Cart
Share