Oscilloscope Specifications

Oscilloscope — Vertical
Model PicoScope 5203 PicoScope 5204
Bandwidth (at probe tip) 250 MHz
Rise time (calculated) 1.4 ns
Input channels 2
Vertical resolution 8 bits
Enhanced vertical resolution 12 bits
DC accuracy ±3%
Input characteristics 1 MΩ in parallel with 15 pF
Input type Single–ended, BNC connector
Input coupling Software selectable AC/DC
Input ranges (full scale) ±100 mV to ±20 V in 8 ranges
Overload protection ±100 V (DC+AC peak)
Oscilloscope — Horizontal
Maximum sampling rate (single shot)
One channel in use
Two channels in use

1 GS/s
500 MS/s
Maximum sampling (repetitive signals) 20 GS/s
Maximum sampling
(continuous streaming mode)
1 MS/s (Record length limited to 20 MS in PicoScope, unlimited when using the supplied SDK)
Buffer memory size
One channel in use
Two channels in use

32 MS/channel
16 MS/channel

128 MS/channel
64 MS/channel
Buffer memory size (in streaming mode) 2 M samples per channel
Waveform buffer Up to 10000 waveforms
Timebase ranges 5 ns/div to 200 s/div
Timebase accuracy
50 ppm
Triggers
Trigger modes Normal, auto, repeat, single, ETS, rapid
Basic triggers Rising / falling edge triggers
Advanced triggers Pulse width, dropout, window, delay, logic, edge with hysteresis
External trigger
Trigger threshold
Resolution
Input characteristics
Bandwidth
Overload protection

Variable up to ±20 V
12 mV typical
BNC, 1 MΩ
150 MHz
±100 V
Spectrum Analyser
Frequency range DC to 250 MHz
Maximum number of bins 1,048,576
Resolution 8 bits
Display modes Magnitude, peak hold, average
Window types Rectangular, Gaussian, triangular, Blackman, Blackman–Harris, Hamming, Hann, flat–top
Arbitrary Waveform Generator
Arbitrary waveform buffer 10 to 8192 samples
Standard waveforms Sine, square, triangle, ramp (up/down), sin (x)/x, Gaussian, half sine, noise, DC
Bandwidth DC to 20 MHz
Special modes Triggering, gating
Sample rate 125 MS/s
Output characteristics BNC, 50 Ω
Resolution 12 bits
Amplitude ±250 mV to ±2 V (±2.5 V with DC offset)
DC offset ±1 V
Auxiliary Input/Output (AUX IO)
Input impedance 100 kΩ
Output impedance 600 Ω
Maximum input voltage 5 V
Input threshold 1.65 V (nominal)
PC Requirements
Minimum Processor: Pentium II processor, or equivalent
Memory: 64 MiB (XP) / 512 MiB (Vista) / 1 GiB (Win 7)
Operating system: 32– or 64–bit edition of Microsoft Windows XP SP2, Vista or Windows 7
Ports: USB 2.0 compliant port
Recommended Processor: 2 GHz Pentium IV processor, or equivalent
Memory: 256 MiB (XP) / 1 GiB (Vista / Win 7)
Operating system: 32– or 64–bit edition of Microsoft Windows XP SP2 (or above), Vista or Windows 7
Ports: USB 2.0 compliant port
Environmental
Operating environment
Temperature range

Humidity

0 °C to 40 °C for normal operation
20 °C to 30 °C for quoted accuracy
5% to 80% RH, non-condensing
Storage environment
Temperature range
Humidity

-20 °C to +60 °C
5% to 95% RH, non-condensing
Physical Properties
Dimensions 170 x 255 x 40 mm
(6.7 x 10.0 x 1.6 in)
Weight 0.9 kg
(31.7 oz)
Software
PicoScope 6 for Windows PicoScope 6 is your complete test and measurement lab in one application. Features include:
Capture modes: oscilloscope, spectrum and persistence.
Channel maths: calculate the sum, difference, product, inverse or create your own custom function using standard arithmetic, exponential and trigonometric functions.
Mask limiting testing: pass/fail, failure count, total count.
Serial Decoding: decode data from a serial bus such as I²C.
Automated measurements
Scope mode: AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak–to–peak, rise time and rising rate.
Spectrum mode: frequency at peak, amplitude at peak, average amplitude at peak, total power, total harmonic distortion (THD % and THD dB), total harmonic distortion plus noise (THD+N), spurious-free dynamic range (SFDR), signal+noise+distortion to signal+noise ratio (SINAD), signal to noise ratio (SNR) and intermodulation distortion (IMD).
Export data formats: comma separated values (CSV), tab delimited (TXT), windows bitmap (BMP), graphics interchange format (GIF), portable network graphics (PNG), MATLAB 4 format (MAT).
Full details for PicoScope 6
Linux drivers 32–bit and 64–bit
Software development kit Includes drivers and example code for various programming languages including C, C#, Delphi, Excel and LabVIEW.
Language Support
Software
PicoScope 6

Full support for: English, Français, Deutsch, Italiano, Español
Menus and dialogs only for: 中文 (简体), 正體中文 (繁體), Čeština, Dansk, suomi, Ελληνικά, Magyar, 日本語, Norsk, Polski, Português, română, Русский, Svenska, Türkçe
Documentation
User’s guide
Installation guide
Programmer’s guide

English
English, Français, Deutsch, Italiano, Español
English
General
Additional hardware (supplied) Carry case
2 x 250 MHz x1/x10 oscilloscope probes
USB 2.0 cable
AC adaptor
User manuals and software CD–ROM
Power supply
AC adaptor
6 V ±5% @ 2.5 A
External adaptor supplied (suitable for USA, UK, Europe and Australasia)
Compliance European EMC and LVD standards
FCC Rules Part 15 Class A
RoHS compliant
Total Satisfaction Guarantee In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days.
Warranty 5 years
Lead time In stock In stock
Price

* US Dollar and Euro prices are approximate.

£1,195·00  
US$1,971·75*
€1.445,95*
£1,795·00  
US$2,961·75*
€2.171,95*

Note: quoted specifications apply when using PicoScope 6 software.