| Oscilloscope — Vertical | |||
|---|---|---|---|
| Model | PicoScope 3204A/B | PicoScope 3205A/B | PicoScope 3206A/B |
| Bandwidth (-3 dB) | 60 MHz | 100 MHz | 200 MHz |
| Rise time (calculated) | 5.8 ns | 3.5 ns | 1.75 ns |
| Input channels | 2 | ||
| Vertical resolution | 8 bits | ||
| Enhanced vertical resolution | 12 bits | ||
| DC accuracy | ±3% of full scale | ||
| Input sensitivity | 10 mV/div to 4 V/div (10 vertical divisions) | ||
| Input characteristics | 1 MΩ ±1% in parallel with 13 pF ±1 pF | ||
| Input type | Single–ended, BNC connector | ||
| Input coupling | Software selectable AC/DC | ||
| Input ranges (full scale) | ±50 mV to ±20 V in 9 ranges | ||
| Analogue offset range 50 mV to 200 mV ranges 500 mV to 2 V ranges 5 V to 20 V ranges | ±250 mV ±2.5 V ±20 V | ||
| Overload protection | ±100 V (DC + AC peak) | ||
| Oscilloscope — Horizontal | |||
|---|---|---|---|
| Maximum sampling rate (single shot) 1 channel in use 2 channels in use | 500 MS/s 250 MS/s | ||
| Maximum sampling rate (repetitive signals) | 2.5 GS/s | 5 GS/s | 10 GS/s |
| Maximum sampling rate (continuous streaming mode) | 1 MS/s using PicoScope > 10 MS/s using the supplied SDK (PC dependent) | ||
| Buffer memory# A models B models | 4 MS 8 MS | 16 MS 32 MS | 64 MS 128 MS |
| Waveform buffer | Up to 10,000 waveforms | ||
| Timebase ranges | 2 ns/div to 200 s/div | 1 ns/div to 200 s/div | 500 ps/div to 200 s/div |
| Timebase accuracy | ±50 ppm | ||
| Sample jitter | < 5 ps RMS | ||
# Shared between active channels
| Dynamic Performance (typical) | |||
|---|---|---|---|
| Crosstalk | Better than 400:1 up to full bandwidth (equal voltage ranges) | ||
| Harmonic distortion | < -50 dB at 100 kHz full scale input | ||
| SFDR | 52 dB | ||
| ADC ENOB | 7.6 bits | ||
| Noise | 180 µV RMS (on most sensitive range) | ||
| Pulse response | < 5% overshoot | ||
| Bandwidth flatness | (+0.3 dB, -3 dB) at scope input, from DC to full bandwidth | ||
| Triggers | |||
|---|---|---|---|
| Basic triggers | Auto, repeat, single, none, rapid (segmented memory) | ||
| Advanced triggers (Ch A, Ch B) | Edge: rising, falling or dual edge with adjustable hysteresis Window: signal enters or exits a user–defined voltage range Pulse width: a negative or positive pulse is wider or narrower than a set width, or inside/outside a range of widths Window pulse width: signal is inside or outside a voltage range for a set time Dropout: signal does not cross a voltage threshold for at least a set time Window dropout: signal does not enter or exit a voltage range for at least a set time Interval: time between two edges is greater or less than a set time, or inside/outside a time range Logic: arbitrary logic state of Channels A, B and EXT matches a user–defined pattern Runt pulse: signal crosses one voltage threshold and returns without crossing the other | ||
| Trigger sensitivity (Ch A, Ch B) | Digital triggering provides 1 LSB accuracy up to full bandwidth of oscilloscope | ||
| Maximum pre–trigger capture | Up to 100% of capture size | ||
| Maximum post–trigger delay | Up to 4 billion samples | ||
| Trigger re–arm time | < 2 µs on fastest timebase | ||
| Maximum trigger rate | Up to 10,000 waveforms in a 20 ms burst | ||
| External Trigger Input | |||
|---|---|---|---|
| Trigger types | Edge, pulse width, dropout, interval, logic, delayed | ||
| Input characteristics | 1 MΩ ±1% in parallel with 13 pF ±1 pF | ||
| Input type | Front panel BNC connector | ||
| Bandwidth | 60 MHz | 100 MHz | 200 MHz |
| Voltage range | ±5 V, DC coupled | ||
| Overvoltage protection | ±100 V (AC + DC peak) | ||
| Function Generator (all models) | |||
|---|---|---|---|
| Standard output signals All models B models | Sine, square, triangle, DC voltage Ramp, sinc, Gaussian, half-sine, white noise, PRBS | ||
| Standard signal frequency | DC to 1 MHz | ||
| Output frequency accuracy | ±50 ppm | ||
| Output frequency resolution | < 0.01 Hz | ||
| Output voltage range | ±2 V with ±1% DC accuracy | ||
| Amplitude flatness | < 0.5 dB to 1 MHz, typical | ||
| SFDR | > 60 dB, 10 kHz full scale sine wave | ||
| Connector type | Front panel BNC with 600 Ω output impedance | ||
| Overvoltage protection | ±10 V | ||
| Sweep modes | Up, down, dual with selectable start/stop frequencies and increments | ||
| Arbitrary Waveform Generator (B models only) | |||
|---|---|---|---|
| Update rate | 20 MHz | ||
| Buffer size | 8 kS | 8 kS | 16 kS |
| Resolution | 12 bits (output step size approximately 1 mV) | ||
| Bandwidth | > 1 MHz | ||
| Rise time (10 to 90%) | < 100 ns | ||
| Spectrum Analyser | |||
|---|---|---|---|
| Frequency range | DC to 60 MHz | DC to 100 MHz | DC to 200 MHz |
| Display modes | Magnitude, peak hold, average | ||
| Window types | Rectangular, Gaussian, triangular, Blackman, Blackman–Harris, Hamming, Hann, flat–top | ||
| Number of FFT points | Selectable from 128 to 1 million in powers of 2 | ||
| PC Requirements | |||
|---|---|---|---|
| Minimum | Processor: Pentium II processor, or equivalent Memory: 64 MiB (XP) / 512 MiB (Vista) / 1 GiB (Win 7) Operating system: 32– or 64–bit edition of Microsoft Windows XP SP2, Vista or Windows 7 Ports: USB 2.0 compliant port | ||
| Recommended | Processor: 2 GHz Pentium IV processor, or equivalent Memory: 256 MiB (XP) / 1 GiB (Vista / Win 7) Operating system: 32– or 64–bit edition of Microsoft Windows XP SP2 (or above), Vista or Windows 7 Ports: USB 2.0 compliant port | ||
| Environmental | |||
|---|---|---|---|
| Operating environment Temperature range | 0 °C to 50 °C (20 °C to 30 °C for quoted accuracy) | ||
| Physical Properties | |||
|---|---|---|---|
| Dimensions (including connectors) | 200 x 140 x 40 mm (approx 7.9 x 5.5 x 1.6 in) | ||
| Weight | < 0.5 kg (approx < 1.1 lb) | ||
| Software | |||
|---|---|---|---|
| PicoScope 6 for Windows | PicoScope 6 is your complete test and measurement lab in one application.
Features include: Capture modes: oscilloscope, spectrum and persistence. Channel maths: calculate the sum, difference, product, inverse or create your own custom function using standard arithmetic, exponential and trigonometric functions. Mask limiting testing: pass/fail, failure count, total count. Serial Decoding: decode data from a serial bus such as I²C. Automated measurements Scope mode: AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak–to–peak, rise time and rising rate. Spectrum mode: frequency at peak, amplitude at peak, average amplitude at peak, total power, total harmonic distortion (THD % and THD dB), total harmonic distortion plus noise (THD+N), spurious-free dynamic range (SFDR), signal+noise+distortion to signal+noise ratio (SINAD), signal to noise ratio (SNR) and intermodulation distortion (IMD). Export data formats: comma separated values (CSV), tab delimited (TXT), windows bitmap (BMP), graphics interchange format (GIF), portable network graphics (PNG), MATLAB 4 format (MAT). Full details for PicoScope 6 | ||
| Software development kit | Includes drivers and example code for various programming languages including C, Excel and LabVIEW. | ||
| Language Support | |||
|---|---|---|---|
| Software PicoScope 6 | Full support for: English, Français, Deutsch, Italiano, Español Menus and dialogs only for: 中文 (简体), 正體中文 (繁體), Čeština, Dansk, suomi, Ελληνικά, Magyar, 日本語, Norsk, Polski, Português, română, Русский, Svenska, Türkçe | ||
| Documentation User’s guide Programmer’s guide Quick Start Guide | English, Français, Deutsch, Italiano, Español, 中文 English English, Français, Deutsch, Italiano, Español | ||
| General | |||
|---|---|---|---|
| Data sheet | English, 中文 (简体), Deutsch, Español, Français, Italiano | ||
| Additional hardware (supplied) | USB 2.0 cable, 2 x oscilloscope probes in probe case, user manuals and software CD–ROM | ||
| PC interface | USB 2.0 | ||
| Power requirements | Powered from USB port | ||
| Compliance | European EMC and LVD standards FCC Rules Part 15 Class A RoHS compliant | ||
| Total Satisfaction Guarantee | In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days. | ||
| Warranty | 5 years | ||
| Ordering Information | |||
|---|---|---|---|
| Model | PicoScope 3204A | PicoScope 3205A | PicoScope 3206A |
| Cat number | PP708 | PP710 | PP712 |
| Lead time | In stock | In stock | In stock |
| Price | £399·00 US$658·35* €482,79* | £599·00 US$988·35* €724,79* | £799·00 US$1,318·35* €966,79* |
| Order online | |||
| Order from a distributor | Find my local distributor | ||
| Model | PicoScope 3204B | PicoScope 3205B | PicoScope 3206B |
| Cat number | PP709 | PP711 | PP713 |
| Lead time | In stock | In stock | In stock |
| Price | £499·00 US$823·35* €603,79* | £699·00 US$1,153·35* €845,79* | £899·00 US$1,483·35* €1.087,79* |
| Order online | |||
| Order from a distributor | Find my local distributor | ||
* US Dollar and Euro prices are approximate. You will be billed in Pounds Sterling (GBP).
Note: quoted specifications apply when using PicoScope 6 software.