Here is your monthly Test and Measurement update.
- More information on the 12 GHz PicoScope 9201
- Tech Tip: PicoLog and Excel
- PicoScope 6 and Resolution Enhance
- New: Linux drivers for PicoScope 2000 and 3000 series
- Questions and answers
- Training courses (new email address)
- Forthcoming exhibitions
- Employment opportunities
- Latest software releases
- About this newsletter
- Contact details
1. More Information on the 12 GHz PicoScope 9201
Since last month’s announcement of the forthcoming PicoScope 9201 12 GHz Sampling PC Oscilloscope, we have been busy designing a full-colour brochure listing the main features and specifications. If you register your interest on our website, we will send you a link to an online copy of the brochure.
In case you missed last month’s newsletter, the PicoScope 9201 is a high-performance sampling oscilloscope with two 12 GHz analogue input channels and a 10 GHz HF trigger input. It is designed specifically to use sequential sampling to capture repetitive signals, and has an effective sampling rate of up to 5 TS/s. These specifications give it the ability to display high-speed serial communications waveforms, time and voltage histograms, FFTs and eye diagrams. It has an extensive menu of automatic measurements, with standard mask tests including SONET/SDH, Fibre Channel, Ethernet and INFIBAND. With its small size (the same as our PicoScope 5000 series) and low price (less than £6,000), we think it will appeal to a wide range of design and test engineers.
Due to the high demand for the PicoScope 9201, we cannot yet give accurate lead times for delivery. Later this month, to ensure that orders are processed fairly, we will be contacting customers who have already expressed an interest to give them an opportunity to place orders. After this, in June, the scope will go on general sale. Orders will be despatched in the order they are received, with the first units being despatched to customers in early July.
If you have an interest in the PicoScope 9201 sampling oscilloscope, we recommend that you register your interest on the website:
Register now for the PicoScope 9201 brochure
2. Tech Tip: PicoLog and Excel
PicoLog, our data-logging software for Windows, can display and export data in a variety of formats. In particular, there are two ways to export your data from PicoLog into Microsoft Excel:
- Static method. This is the simplest method. First, capture your data in the normal way using PicoLog Recorder. Next, click “File”, then click “Save as”, change the “Save as type” to “Comma-separated values files (*.csv)”, type in a file name and click “Save”. You can then open the resulting .csv file using Excel.
- Dynamic method. This method uses Windows DDE (Dynamic Data Exchange) to allow Excel to display your data as it changes. First, when you install PicoLog, you need to choose “Custom Setup” and ensure that the “Programming Examples” for your device are installed. You will then find in your Pico installation directory an example Excel (.xls) file that demonstrates how to acquire the data using an Excel macro. Open the .xls file (the program may warn you about the macros embedded in the file), then select “Tools”, “Macro”, “Macros”. You will see a number of macros listed. Clicking the “Edit” button will show you the Visual Basic code behind them, which you can edit to suit your own application.
3. PicoScope 6 and Resolution Enhance
PicoScope 6, our oscilloscope software, supports all of our USB oscilloscopes and is regularly updated. This month, we’ll take a closer look at one of its advanced features, Resolution Enhance.
Every digital oscilloscope on the market has a fixed input resolution that is measured in bits. The larger this number, the more distinct voltage levels the scope can measure. An 8-bit scope, for example, can distinguish 256 (2 to the power of 8) levels. This means that, if you set the scope to a measuring range of -2 volts to +2 volts, the total range of 4 volts is divided into 256 equal steps of 15.625 mV each. This is normally the smallest voltage change that the scope can detect.
PicoScope 6, in Resolution Enhanced mode, applies a moving-average filter to the incoming data. This filters out noise and increases the scope’s apparent resolution, at the expense of narrowing the frequency response. The longest filter available can increase the resolution by up to 4 bits, making an 8-bit scope behave like a 12-bit scope and boosting a 12-bit scope to around 16 bits. This increased number of bits translates to a higher dynamic range (8 bits is 48 dB, 12 bits is 72 dB and 16 bits is 96 dB), which can make a low-resolution scope suitable for higher-resolution audio measurements as long as the input signal remains within the pass band of the filter.
To find the Resolution Enhance controls in PicoScope 6, click the Channel Options button on the toolbar. You can find further information in the PicoScope 6 manual, which is free to download.
4. New: Linux Drivers for PicoScope 2000 and 3000 Series
The new Linux driversallow programmers to control the PicoScope 2000 Series and PicoScope 3000 Series scopes using their own software. The driver is supplied as an RPM package for Fedora Linux 8, and is accompanied by example programs in C.
The new drivers have been thoroughly tested, but we cannot guarantee that the software will be stable under all conditions. We would like to hear from you if you experience any problems or have any suggestions for improvements.
5. Questions and Answers
Here is a selection of the questions that have cropped up recently on our support forum.
- Q. Does Pico software recognise a device connected to a USB hub using a Serial to USB Converter? –Keith (Southend)
- A. Yes it does. If you have one of our serial-port devices then you can certainly use a USB to serial converter. You will need to find out what COM port it has been assigned to in Device Manager, so that when you are in PicoLog you can assign the correct COM port.
- Q. I just bought a TC-08 to monitor and evaluate a complex solar heater. I don’t need all 8 temperature inputs. I was wondering if it was possible to somehow convert one or two channels into an on or off state to monitor when certain pumps come on or go off, in relation to the temperature. –Brendan
- A. The TC-08 can also measure voltages in the range ±70 mV, so you could convert your switch states to this voltage range and monitor them in PicoLog.
- Q. I am trying to install my ADC-42 purchased in 2001! I have an old, incomplete set of Pico software on floppy discs, version 5.04.4 - 16 bit. Please can you tell me which version to download for Windows XP (SP2) just to run a simple spectrum analyser? –Forum guest
- A. The latest version of the application software is R5.17.1, and that is compatible with your product. Remember to uninstall the older version before installing the newer version. (Note: we no longer sell the ADC-42, but we continue to look after our customers by offering free technical support and free downloads of the PicoScope 5 software.)
6. Training Courses (New Email Address)
In response to customer demand, we are now offering regular training courses on data logging and EnviroMon for UK Pico users. The courses will be suitable for beginners and advanced users alike and can be tailored to individual requirements.
We shall begin by holding courses at the new Pico headquarters, but on-site courses will be available by request. We have set up a dedicated email address to ensure that your enquiry gets dealt with promptly: please email courses@picotech.com to register your interest.
7. Forthcoming Exhibitions
Full details of upcoming exhibitions and training dates can be found on the exhibitions page.
8. Employment Opportunities
Due to our continuing growth, we have vacancies for the following positions:
- Development Engineer - Analogue Hardware
- Development Engineer - Hardware
- Development Engineer - Windows Desktop Application Software
- Development Engineer - Windows Device Driver Software
Find more details of these positions and complete an online application form
We look forward to hearing from you if you want to be part of a growing company at the leading edge of test equipment design.
9. Latest Software Releases
As soon as we release new software, it is made available for FREE download from our website. To check which version you are using, start the software (PicoScope, PicoLog or EnviroMon) and select HELP | ABOUT.
The current releases are:
- PicoScope 5: R5.19.1
- PicoScope 6: R6.0.13
- PicoLog: R5.19.1
- EnviroMon: R5.16.2
To download the latest software please visit the software downloads page
(Note: the above web page also contains a link to our 'what’s new' page which describes recent changes and additions to the software.)
10. About this Newsletter
Back issues of this newsletter are available online at http://www.picotech.com/maillist.html
As this is an opt-in email list, we add names only on request. Pico Technology will not pass your name to any third party.
To subscribe or unsubscribe from this newsletter please follow the links in your email, or visit http://www.picotech.com/maillist.html
Recommend this newsletter to a friend
To make sure that your Pico newsletter reaches your inbox every month, please add listmaster@picotech.com to your email Address Book or Safe List.
11. Contact Details
James House
Colmworth Business Park
St Neots
Cambridgeshire
PE19 8YP
United Kingdom
| Phone: | +44 (0)1480 396 395 | |
|---|---|---|
| Fax: | +44 (0)1480 396 296 | |
| Email: | sales@picotech.com | |
| Web: | www.picotech.com | |
Cart
Email